NM20

MULTIFUNCTION PROTECTION FOR LARGE SIZE MOTORS (PRO)

More details...

Price on request

NM20

The relay type NM20 can be used for protection of large size motors in MV systems.
For any grounded systems (solidly grounded, ungrounded or Petersen coil and/or resistance grounded) the protection can be used on feeders of any lenght.

Specifications

Key: standard optional alternative

Applications
• Motor
Protection functions
• Pt100 thermometric probes (26)
• Undervoltage (27)
• Positive seq. undervoltage (27V1)
• Reverse active overpower (32R)
• Phase undercurrent (37)
• Directional active underpower (37P)
• Loss of field (40)
• Negative sequence overcurrent (46)
• Phase reversal (47)
• Thermal image (49)
• Phase overcurrent (50/51)
• Residual overcurrent (50N/51N)
• Locked rotor (51LR(48)/14)
• Minimum power factor (55)
• Overvoltage (59)
• Residual overvoltage (59N)
• Negative seq. overvoltage (59V2)
• Maximum number of starting (66)
• Ground directional overcurrent (67N)
• Underfrequency & overfrequency (81U 81O)
• High impedance restricted earth fault (87NHIZ)
• Breaker failure (BF)
Monitoring and control functions
• CB diagnostic
• Cold Load Pickup (CLP)
• CTs monitoring (74CT)
• Digital Fault recording (DFR)
• Fault and event logging (SER & SFR)
• Logic selectivity
• Multiple setting profiles
• Programmable Logic Controller
• Self-test
• Trip circuit supervision (74TCS)
• VTs monitoring (74VT)
Hardware
• 2 binary inputs + 6 output relays + 8 LEDs
• Auxiliary power supply 110-230 Vac/dc
• Auxiliary power supply 24-48 Vac/dc
• Flush, projecting, projecting, rack, with separate MMI
• Network module with Ethernet FX port (optical fiber)
• Network module with Ethernet TX port (copper RJ45) + RS485 port
• Nominal current 1/5 A selectable by DIP-switch
• RS485 port (unavailable with Ethernet FX port)
• Standard CT amperometric inputs 1/5 A
Communication
• IEC 61850 Protocol
• Modbus RTU RS232 protocol
• Modbus RTU RS485 / IEC 870-5-103 / DNP3 protocol
• Modbus TCP/IP protocol (network board must be provided)

  • application MOTOR
  • ANSI protection Negative sequence overcurrent (46)|Minimum power factor (55)|Residual overvoltage (59N)|Residual overcurrent (50N/51N)|Locked rotor (51LR(48)/14)|Undervoltage (27)|Pt100 thermometric probes (26)|Positive seq. undervoltage (27V1)|Reverse active overpower (32R)|Negative seq. overvoltage (59V2)|Phase undercurrent (37)|Loss of field (40)|Thermal image (49)|Phase overcurrent (50/51)|Underfrequency & overfrequency (81U 81O)|Ground directional overcurrent (67N)|Breaker failure (BF)|Maximum number of starting (66)|Overvoltage (59)|High impedance restricted earth fault (87NHIZ)|Phase reversal (47)|Directional active underpower (37P)